Your cart is empty!
VLF and DC test capabilities combined in one unit (60 kg). Suitable for testing cables (XLPE, PE, EPR, PILC etc), capacitors, switchgear, transformers, machines (IEEE 433), insulators and bushings. VLF (0.1Hz to 0.02Hz), DC (+/-), cable fault conditioning (burning) and sheath/jacket testing modes all included. Fully automatic or manual cable test sequences complying with International Standards/Guides such as IEEE 400.2, VDE 0276 and CENELEC. True symmetrical sinusoidal, load independent, output waveform across the full load range. Real-time display of actual output wave form. Easy to use, ergonomic, menu guided, large backlit user interface. Large output load capability (up to 5uF). Automatic and integrated load capacitance measurement with optimum frequency selection. Storage of test results for later retrieval or download to a PC/Laptop. Optional Accessories: HVD,HVA TD60
Optional Accessory for HVD,HVA60-DC/VLF and HVD,HVA90_DC-VLF. Tan Delta or Power Factor tester used to determine the power factor of cabl..
Test voltage 80kV max at 61.8Hz. Fully automatic operation. Rechargeable batteries. RS232C interface. ..
Optional Accessory for HVD,HVA60-DC/VLF and HVD,HVA90_DC-VLF. Tan Delta or Power Factor tester used to determine the power factor of cables,..
VLF, DC and Jacket/Sheath testing. Sinusoidal: 0 - 94 kV peak, 0 - 66 kV rmsDC: ± 0 - 90 kV and Squarewave: 90 kV. The high power HVA94 Test..
Tags: , 60kv, hva60, vlf/dc test set