The 3Z RF Vision antenna alignment tool replaces a compass, GPS, and range finder. This antenna alignment tool is effective and r..
Handheld digital ELF gauss meter. Maintains accuracy regardless of orientation. Applications include detecting magnetic field emissions f..
Magnetic measuring equipment, portable gaussmeter. Built-in software eliminates the need for complex calibration procedures. Key features ..
Portable Spectrum Analyser, 9 kHz to 9.4 GHz comes attached with directional antenna. DANL -155 dBm (1 Hz) with preamp DANL -170 dBm (1 H..
The Aeroflex 8800SX expands upon the features of the 8800 Series with a new 10 MHz external reference and new software capabilities to furth..
Aeroqual Dust Sentry Profiler Outdoor dust monitor. This will monitor data and store the information in the cloud. This instrument will log ..
Portable ozone monitor fitted with low concentration-range detection head. Operating range 0~0.5ppm ozone with display in ppm or mg/m3. G..
Double ridge guide horn antenna. 700MHz to 18GHz frequency range. Continuous power 300W. 50ohm 200V/m maximum radiated field. Type N(F) c..
The ALL-TEST5PRO is a comprehensive electrical motor circuit analyser designed for stand alone troubleshooting, and QA of stored new or r..
The EBT731 Balometer Electronic Balancing Tool features a detachable multi-purpose digital manometer that can be used with the following ..
Anritsu MP534A dipole antenna 25 to 520MHz and MP651A 470 to 1700MHz. ..
Anritsu MS2712E portable hand held spectrum analyser 9 kHz to 4 GHz, DANL -162 dBm in 1 Hz RBW, RBW 1 Hz to 3 MHz. Tracking generator -50 ..
Anritsu MW82119B Passive Intermodulation (PIM) analyser with measurement frequency 2100 MHz and Site Master (cable and antenna analysis) o..
The Anritsu MW82119B Passive Intermodulation (PIM) analyser with frequency option has a Cellular 850 MHz band, is portable battery-operate..
Cable and antenna analyser, frequency range 2Mhz to 4GHz. Measures return loss, VSWR, cable loss, and Distance To Fault. Suitable for leg..
Cable and antenna analyser, frequency range 2 MHz to 4 GHz. Built-in power meter that measures 50 MHz to 4 GHz, -33 dBm to +20 dBm.&..
Anritsu antenna and cable analyser 2MHz to 4GHz and spectrum analyser 100KHz to 4GHz. DANL -152dBm. Options included, indoor outdoor Cover..
Anritsu antenna and cable analyser 2MHz to 4GHz and spectrum analyser 100KHz to 4 GHz. DANL -152dBm. Measures return loss, VSWR, cable lo..
Microwave antenna and cable test set. Portable single port analyser, providing return loss (SWR) insertion loss and distance to fault meas..
Microwave antenna and cable analyser, frequency range 20 MHz to 20 Ghz with 110 dB dynamic range. Performs coaxial and waveguide system m..
Waveguide Adaptor component used along with Anritsu, S820A & S820D. Please request for the suitable type. ..
The ARL NGARA is a Class 1 environmental noise logger designed for unattended monitoring that offers full measurement flexibility. It can..
Beamex CMX Light calibration software for single workstation. ..
Beamex external pressure modules compatible with MC6, MC5, MC4, MC2 MC5-IS, MC2-IS and MC5P calibrators. Various rangers available, please i..
NATA certified MC6 provides calibration capability for pressure, temperature, electrical and frequency signals. HART communication and CM..
NATA certified MC6 provides calibration capability for pressure, temperature, electrical and frequency signals with HART communication and D..
The TK-3 Proximity System Test simulates shaft vibration and position for calibrating proximity probes. The TK-3 uses a removable spindle mi..
Ambient Temperature: -40°C to +40°C Connector: N Coolant: Dry (Convection cooled) Finish: Black anodized fins. Frequency Range and VSWR: ..
Multi-ranging DC power supply allowing any combination of the rated 600 V and 8.5 A up to the maximum output power of 3000 W...
Automatic calibration testing and data management system for the BW microclip gas detection equipment. Carries out fully automatic "hands-..
Continuous LCD shows real time gas concentrations. Simple 1 button operation. Measures:- H2S 0~100ppm (1ppm resolution), CO 0~500ppm (1pp..
Honeywell BW GasAlert Extreme single gas sensor for NH3 (Ammonia). There are two in the kit including a bump station with 50 ppm gas. ..
The BW GasAlertMax XT II is a confined space monitor that comes with a built-in sampling pump. Will sample at up to 20 m. Simple 1 button op..
Motorized sampling pump that provides 300ml/min for remote sampling up to 18m away. Runs continuously for 30hrs on batteries. Includes 3m..
Cable and pipe avoidance and location tool with depth measurement. Simultaneous dual 33+131 kHz frequency will assist in the detection of sm..
This cavity/down hole inspection camera has a Sony HD image sensor housed in a waterproof casing (8 bar, 80 m) with 360/180° pan tilt capabi..
135M-12 Strobex to suit Chadwick Helmuth Vibrex 2000 kit. For setting the timing on helicopter rotor blades. ..
Weatherproof compact power analyzer & logger. Certified to IEC61000-4-30, Class A. Includes WiFi and mobile interfaces and GPS time sync..
Range -1 to 1 bar (15 psi) NATA certified pressure gauge. Accuracy, +/-0.1% of reading between 20 to 100% of full scale, +/-0.02% of full sc..
Range -1 to 138 bar (2,000 psi) Nata certified pressure gauge. Accuracy, +/-0.1% of reading between 20 to 100% of full scale, +/-0.02% of fu..
Range -1 to 138 bar (2,000 psi) Nata certified pressure gauge. Accuracy, +/-0.1% of reading between 20 to 100% of full scale, +/-0.02% of..
Range 20Bar resolution 1mBar. Accuracy 4 to 20Bar +/-0.1% of reading. 0 to 4Bar +/-4mBar. It Has a 6000 point logging capability. Logging..
Range 210Bar resolution 0.01Bar. Accuracy 40 to 200Bar +/-0.1% of reading. 0 to 40Bar +/-0.04Bar. Has a 6000 point logging capability. Lo..
Range 700Bar resolution. 0.01Bar accuracy. 1% of reading. Has logging capability. 6000 point pressure logging capability. Logging interva..
Range 700Bar resolution. 0.01Bar accuracy. 1% of reading. Has logging capability. 6000 point pressure logging capability. Logging interval ..
Range 70Bar resolution 0.001Bar. Accuracy 14 to 70Bar +/-0.1% of Reading 0 to 14Bar +/-14mBar. Has a 6000 point logging capability. Loggi..
Range 7Bar resolution 0.1mBar. Accuracy 1.4 to 7Bar +/-0.1% of reading. 0 to 1.4Bar +/-1.4mBar. Vacuum +/-17.5mBar. Has a 6000 point logg..
Rugged, durable, shock-proof construction, Stable calibration - linear accuracy - no zero adjustment. For use in Zone 0, Zone 1 hazardous ar..
Rugged, durable, shock-proof construction, Stable calibration - linear accuracy - no zero adjustment. Heavy duty sealed unit with double 'O'..
Measures voltage, current, resistance and frequency. Up to 15 analog sensor inputs. Each channel is independent and supports: one isolate..
Channel expansion module for DT80 data loggers. Adds 20 full datataker channels to the logger...
Includes a built in GSM modem for internet access to the device. Measures voltage, current, resistance and frequency. Up to 5 analogue (±..
Analog inputs 32 isolated and 48 single ended inputs. 2x 4 digital input types. 2x serial sensor ports, Modbus capability, , 4x SDI12 cha..
Analog inputs 32 isolated and 48 single ended inputs. 2x 4 digital input types. 2x serial sensor ports, Modbus capability, 4x SDI12 ch..
Ferrous/Non Ferrous metal coating thickness tester with storage of up to 100,000 readings. Supplied with external probe, calibration standa..
Measures the force required to pull a specified test diameter of coating away from its substrate using hydraulic pressure. Pressure is di..
Single phase variac. 240 V ac input, 0 to 270 V ac output at 17 A. Input and output connections must be wired up under a prot..
Portable, direct-reading residual chlorine meter for water analysis. Range 0 to 2 mg/L [ppm]. Reagent-free measurement with electrode, 3 m..
Set of 4 current clamp/probes, range 0 to 10A RMS. Max conductor size 12mm dia. Suitable for power quality analysers DRA-BMI,PG4400, DRA-..